Water chillers
AQUACIATPOWER LD
ELECTRICAL
AQUACIATPOWER LD ST Power circuit
SPECIFICATIONS
602C 650C 750C 800C 1000C 1100C 1250C 1350C 1500C 1600C 1750C 2000C
Basic unit (excluding pump)
Nominal unit current draw(1) A Maximum unit input power (2) Cosine Phi unit at maximum power (2) Maximum unit current draw (Un-10%)(3) A Maximum unit current draw (Un)(4) A A Maximum start-up current, standard unit (Un)(5) A Maximum start-up current, unit with soft starter (Un)(5) A
(1) (2) (3) (4) (5)
Conditions equivalent to the standardised Eurovent conditions (water exchanger water inlet/outlet temperature = 12°C/7°C, outdoor air temperature = 35°C). Power input, compressors and fans, at the unit operating limits (saturated suction temperature 15°C, saturated condensing temperature 68.3°C) and nominal voltage of 400 V (data given on the unit name plate). Maximum unit operating current at maximum unit input power and 360 V. Maximum unit operating current at maximum input power and 400 V (values given on the unit name plate). Maximum instantaneous start-up current at operating limits (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). Fan motor electrical data: at Eurovent equivalent conditions and motor ambient air temperature of 50 °C at 400 V: 3.8 A, start-up current 20 A, power input 1.75 kW
AQUACIATPOWER LD HE Power circuit
602C 650C
750C
800C 1000C 1100C 1250C 1350C 1500C 1600C 1750C 2000C
Nominal unit current draw(1) A Maximum unit input power (2) Cosine Phi unit at maximum power (2) Maximum unit current draw (Un-10%)(3) A Maximum unit current draw (Un)(4) A A Maximum start-up current, standard unit (Un)(5) A Maximum start-up current, unit with soft starter (Un)(5) A
(1) (2) (3) (4) (5)
Conditions equivalent to the standardised Eurovent conditions (water exchanger water inlet/outlet temperature = 12°C/7°C, outdoor air temperature = 35°C). Power input, compressors and fans, at the unit operating limits (saturated suction temperature 15 °C, saturated condensing temperature 68.3 °C) and nominal voltage of 400 V (data given on the unit nameplate). Maximum unit operating current at maximum unit input power and 360 V. Maximum unit operating current at maximum input power and 400 V (values given on the unit name plate). Maximum instantaneous start-up current at operating limits (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor). Fan motor electrical data reported upstream the variable speed drive at Eurovent equivalent conditions and motor ambient air temperature of 50 °C at 400 V: Current 3.0 A; Start-up current 20 A; Power input: 1.75 kW.