references
KNX PID control system on water
CODING
FOR UNITS IN RECIRCULATED AIR APPLICATION ONLY
Kvs valves = 2.5 max - G 1/2” max.
CONTROL UNIT Factory-set and wired electronic PID controller Display terminal NP 16 bar valve with 24 V floating actuator Fittings not included Terminal: V: flush-mounted, factory fitted Terminal: H: wall-mounted, to be wired by fitter Terminal: SH: wall-mounted, to be wired by fitter + supply air limit temperature sensor. Ranges: all ranges except Cassettes, please consult us !
For stock size 600 and Melody2 (3): controller unit and valves in kit supplied separately. Fuse disconnect switch included. Excluding self-balancing 2-way valves** controller with disconnect switch. (1) SH option: not available
V H SH
Code
Code
WATER CONTROL (24 V/3-POS. ACTUATOR)
2-pipe system Heating only - 1 four-way valve
- 1 self-balancing 2-way valve** E3000H E3000V E3000SH(1) E3000H E3000SH(1) E3001V E3001H E3001SH(1) E3002H E3002V E3002SH(1) E3002H E3002SH(1) E3003V E3005V E3003H E3003SH(1) E3005H E3005SH(1) E3006H E3006V E3006SH(1) E3006H E3006SH(1) E3007V E3009V E3007H E3007SH(1) E3009H E3009SH(1) E038556 E047581 E048804 E047601 E047641 ND ND ND ND Included on size 900 and Mélody2 E047661 E048805 E047681 ND ND ND E038563 E038571 E047501 E048803 E047521 E047501 E048803 E047521 E047561 ND ND ND ND ND ND ND
- 1 four-way valve* Cooling only - 1 four-way valve
- 1 self-balancing 2-way valve**
- 1 four-way valve* Automatic heating/cooling with changeover sensor fitted - 1 four-way valve* Cooling only + electric with deadband - 1 four-way valve
- 1 self-balancing 2-way valve**
2-pipe system with electric heater (2 300 W max.)
- 1 four-way valve* Automatic heating/cooling + electric heater with changeover sensor fitted - 1 four-way valve* Additional charge for a capacity of 2 000 W to 4 600 W.
4-pipe system - 2 two-way valves
E3040V - 2 self-balancing 2-way valve** E3040H E3040SH(1) E3040H E3040SH(1) E3041V E3041H E3041SH(1)
- 2 two-way valves*
Mandatory additional charges for valves with Kvs > 2.5 Additional charge for 1 x 2-way valve, 3/4” Kvs 4 Additional charge for 1 x 4-way valve, 3/4” Kvs 4
COADIS LINE 932 - 934 COMFORT LINE T6 Melody2 size 9x
(1) Option not available for COADIS LINE and MELODY2 (2) Custom COADIS LINE: possible from min of 10 CUs (3) Self-balancing two-way valve for Melody2: contact us * 3-way valve(s) with bypass. ** Valves to be set on-site / Custom equipment - Not held in stock / for 2T changeover operation, please contact us. For 4-tube units: - COADIS LINE 600: cooling valve fitted/Heating valve supplied in kit - COADIS LINE 900: cooling and heating valve supplied in a kit - MAJOR LINE: cooling valve fitted/Heating valve supplied in kit - COMFORT LINE: cooling and heating valve factory-fitted
Note: the prices for a dial room terminal are the same as those for a display terminal. Please specify the desired type of terminal at time of order. Dial terminal available in wall-mounted version only.
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.01 A
425
V3000 KNX
4
MAJOR LINE COMFORT LINE
COADIS LINE - MELODY2