references
Comfort Unit Controls
CODING
FOR UNIT FOR RECIRCULATED AIR APPLICATIONS ONLY
Description
Function Heating and cooling Control on ventilation Temperature range + 5 °C to + 30 °C Components 1 sensing element - bimetal - changeover switch 1 temperature adjustment button 1 unipolar on/off (0/1) switch 1 manual heating/cooling (winter/summer) toggle switch 1 x 3-speed ventilation switch Supply voltage 230 V - 50 / 60 Hz Breaking capacity 3 A, inductive circuit (motor) L x W x H = 127.5 x 75 x 25.5 mm Function Heating/cooling, with extra automatic changeover thermostat Control on ventilation
Application
Code
RTR-E 7015
All comfort units Water coil only
5201023
RTR-E 7009
Temperature range + 5 °C to + 30 °C Components 1 sensing element - Bimetal - Changeover switch 1 temperature adjustment button 1 unipolar on/off (0/1) switch 1 x 3-speed ventilation switch Supply voltage 230 V - 50 / 60 Hz Breaking capacity 3 A, inductive circuit (motor) L x W x H = 127.5 x 75 x 25.5 mm Function Heating and cooling Regulation on: - Water coil solenoid valve - Electric heater with or without relay Permanent ventilation
COMFORT LINE / MAJOR LINE Air handling unit COADIS LINE Water coil only
7124612
RTR-E 7012
Temperature range + 5 °C to + 30 °C Components 1 sensing element - Bimetal - Changeover switch 1 temperature adjustment button 1 unipolar on/off (0/1) switch 1 manual heating/cooling (winter/summer) toggle switch 1 x 3-speed ventilation switch Supply voltage 230 V - 50 / 60 Hz Breaking capacity 3 A, inductive circuit (motor) 6 A, resistive circuit (electric heater, 1 400 W max.) L x W x H = 127.5 x 75 x 25.5 mm Function Heating only or cooling only Control on water coil solenoid valve Permanent ventilation Temperature range + 5 °C to + 30 °C
COMFORT LINE / MAJOR LINE - Electric heater, 1 400 W max. Air handling unit - Electric heater, 1 400 W max. COADIS LINE 900 - Electric heater, 3 000 W max. “Relay integrated into the unit” COADIS LINE 600 - Electric heater, 1 400 W max.
5201024
COADIS LINE / MAJOR LINE Air handling unit
RTR-E 7011
Components 1 sensing element - Bimetal - Changeover switch 1 temperature adjustment button 1 unipolar on/off (0/1) switch 1 x 3-speed ventilation switch Supply voltage 230 V - 50 / 60 Hz Breaking capacity 3 A, inductive circuit (motor) 6 A, resistive circuit (electric heater, 1 400 W max.) L x W x H = 127.5 x 75 x 25.5 mm
5201018
COADIS LINE Water coil only
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.01 A
413
Comfort Unit Controls
4