references
Compact air-air rooftop units
PJ range
MODEL
IPJ 1 0090 2
NUMBER NOMENCLATURE
A 3 3 4 U 5 C0 6 AA 7 000 8 0 9
• D: • E: • F: • H: • I: • J: • K: • L: • N: • P: • R: • S: • T: • U: • V: • X: • Y:
N 10
B 11
E 12
0 13
000 14
0000 15
0000 16
0 17
0 18
T100 19
SF0 20
P00 21
000 22
C100 23
Group 1: Unit type • IPJ: air/air heat pump • RPJ: air/air cooling only Group 2: Unit model • 1 circuit: 0090 / 0120 / 0140 / 0160 / 0180 / 0190 • 2 circuits: 200 / 0220 / 0240 / 0280 / 0320 / 0360 / 0380 Group 3: Version of the series Group 4: Electrical power • 3: • 4: 400V / 3ph + N / 50Hz 400V / 3ph / 50Hz
G4 low pressure drop + stop-drop G4 + F6 G4 + F6 + stop-drop G4 + F7 + stop-drop G4 + F8 G4 + F8 + stop-drop G4 + F9 G4 + F9 + stop-drop (G4 + F7) low pressure drop + stop-drop (G4 + F9) low pressure drop + stop-drop F6 + F7 + stop-drop F6 + F8 F6 + F8 + stop-drop F6 + F9 F6 + F9 + stop-drop F7 + F8 + stop-drop F7 + F9 F7 + F9 + stop-drop F8 + F9 F8 + F9 + stop-drop
Group 17: Unused Group 18: Unused Group 19: Sensors 0000 Without options H: Smoke detector sensor A: Air quality sensor for environment C: Air quality sensor duct-mounted P: Air quality sensor on the pLAN network 1: 1 sensor RS485 2: 2 sensors RS485 3: 3 sensors RS485 4: 4 sensors RS485 5: 1 sensor NTC T: Ambient temperature sensor H: Ambient temperature+humidity sensor P: Ambient sensor on the pLAN network
• G: G4 + F7
• M: (G4 + F7) low pressure drop • O: (G4 + F9) low pressure drop • Q: F6 + F7
Group 5: Type of refrigerant • U: R410A Group 6: Flow + Assembly
Group 20: Free-cooling + Outdoor humidity SF0 Without free-cooling 1: Outdoor humidity sensor on the unit 2: Outdoor humidity sensor on pLAN network T: Thermal free-cooling M: Thermoenthalpic free-cooling E: Enthalpic free-cooling F: Free-cooling
• W: F7 + F8
• CR: Cross flow with lower return plug-fan and cooling recovery circuit recovery
• Z: • 1: • 2:
Group 12: Type of outdoor fan • A: • E: AC (2-speed) EC (electronic)
Group 21: Terminal + Unit communication 000 Without terminal + stand-alone + without card M: Comunication card RS485 Modbus/Carel E: Comunication card Ethernet PCoWeb L: Comunication card RS485 LonWorks® B: Comunication card Ethernet BACnetTM C: Comunication card RS485 BACnetTM K: Comunication card RS485 Konnex 0: Stand-alone unit 1: Master unit 2: Slave unit P: Graphic terminal in the electric panel T: User terminal in the electric panel R: User terminal in panel + graphic terminal remote up to 50 m S: User terminal in panel + graphic terminal remote up to 200 m N: Graphic terminal in panel + graphic terminal remote up to 200 m
Group 13: Insulation Group 7: Coil coating : Outdoor - Indoor • • • • • A: B: C: D: E: Aluminium Polyurethane Inera® Copper Blygold® • 0: • 1: Without insulation Insulation Euroclass A2-s1, d0 (M0).
000
Without optional accessories A: Condensate drain pan in stainless steel 1: Overpressure management
Group 8: Heating • 000: Without auxiliary heating • G0: Gas burner Power output: Low (L) / Nominal (N) / High (H) • G1: Boiler + hot water coil Power output: Low (L) / Nominal (N) / High (H) • E0: Electrical heaters Power output: Low (L) / Nominal (N) / High (H) • B0: Hot water coil Standard (S) or Great cold (C) Group 9: Protection for low outdoor temperature • 0: • 1: • 2: Without protection Kit for outdoor temperature <-10ºC Kit for outdoor temperature <-14ºC 0000 Without optional accessories A: Maritime packing 1: Outdoor coil protective grille A: Antivibration mounts 1: Stop-drop at the fresh air intake 000
Group 16: Passive recovery 0000 Without optional accessories 1: Filters G4 2: Filters G4 low pressure drop 3: Filters G4 + F6 A: Wheel speed with on/off control B: Wheel speed with variable control 1: Channel spacing of 2.0 mm 2: Channel spacing of 2.5 mm A: Material: Aluminium B: Material: Aluminium with epoxy C: Material: Hybrid wheel D: Material: aluminium with silicagel
Group 22: Miscellaneous item 1 Without options