Water chillers and air-to-water heat pumps
STD
VERSION: TECHNICAL CHARACTERISTICS
CIATCooler LP / ILP
(kW)
90VSTD
7.75 EER ESEER (kW) 2.29 2.61
100VSTD
9.15 2.31 2.59
120VSTD
10.00 2.51 2.81
160VSTD
12.60 2.60 2.94
180VSTD
14.40 2.49 2.85
200VSTD
18.80 2.32 2.71
240VSTD
19.70 2.51 2.97
280VSTD
22.40 2.49 2.98
320VSTD
24.90 2.73 3.29
360VSTD
28.70 2.59 3.14
Cooling
(kW)
(kW) COP SCOP Heating Prated (kW) SCOP
7.31 2.97 3.11 121% 16.77 3.59 140% Prated (kW) 12.73 6500
8.90 2.94 3.12 122% 19.19 3.63 142% 14.70 7000
9.90 3.00 3.07 120% 21.82 3.57 140% 16.72 10000
12.90 2.97 2.95 115% 26.33 3.42 134% 24.30 12200
14.20 3.01 2.95 115% 31.31 3.35 131% 27.32 12200 20
18.40 2.80 3.07 120% 38.59 3.42 134% 34.90 16000
19.60 2.99 3.07 120% 41.71 3.71 145% 39.44 20000
22.40 2.98 2.95 115% 44.94 3.66 143% 42.83 24400
24.80 3.08 2.95 115% 51.08 3.61 141% 47.04 24400
28.20 3.01 3.17 124% 65.47 3.71 145% 58.00 24400
3/h)
1 fan 2.2 1.46 973 3/h) 3/h) 3/h) 3.1 2.3 Indoor 2.2 6.2 2.2 1.77 1027 3.7 3.2 2.7 7.4 3.0 2.33 837 4.3 2.9 3.1 8.8 4.0 2.83 734 5.7 4.7 4.1 11.3 4.0 2.83 734 6.2 2.9 4.3 12.7 2 x 3.0 4.68 1082 7.5 4.2 4.7 15.0 2 x 3.0 4.66 837 8.5 3.2 6.2 17.2
2 2 x 4.0 5.3 705 9.6 4.0 7.2 19.2 2 x 4.0 5.66 734 11.7 2.1 8.3 23.6 2 x 4.0 5.66 734 12.8 2.6 8.6 26.0
Gas threaded 1 1/4" M 1 1/2" M Scroll 1/1/1 2/2/1 2" M
Copeland 3MAF 32 cST. Danfoss POE 160 SZ. ICI Emkarate RL 32 CF. Mobil EAL Artic 22 CC 3.0 3.3 3.3 3.3 6.2 2 x 3.3 2 x 3.3 2 x 3.3 2 x 3.3 2 x 6.2
R-410A Refrigerant 2 088 Charge (kg) 2 e) 5.9 12.3 6.1 12.7 6.6 13.8 6.9 14.4 7.6 15.9 9.2 19.2 12.3 25.7 12.4 25.9 14.9 31.1 15.4 32.2
400 V / III ph / 50 Hz (±10%) 3 Wires + Ground + Neutral 15.2 absorbed Fan (A) Control (A) Total (A) 5.0 0.9 21.1 1117 860 1447 Weight 302 306 310 315 372 379 17.3 5.0 0.9 23.2 20.5 6.9 0.9 28.3 25.4 8.9 0.9 35.2 1398 860 1727 390 397 388 396 30.5 8.9 0.9 40.3 34.6 13.8 1.8 50.2 2113 860 1447 564 579 644 659 676 692 41.0 13.8 1.8 56.6 45.9 17.8 1.8 65.5 2673 860 1727 710 728 716 733 50.8 17.8 1.8 70.4 61.0 17.8 1.8 80.6
Cooling capacity calculated in accordance with the EN-14511-2013 standard given for outlet water temperature conditions of 7ºC and 35ºC outdoor temperature. Heating capacity calculated in accordance with the EN-14511-2013 standard given for outlet water temperature conditions of 45ºC and 6ºC WB outdoor temperature. Total power input by compressor, motorised fan and electronic control under nominal conditions, calculated in accordance with the EN-14511-2013 standard. Options are not included. Values calculated in accordance with the EN-14825-2013 standard given for bivalente temperature of -5ºC in average climate and 2ºC in warmer climate.
With the transport brackets the machine is 106 mm higher.