references
Air filter
Epure function for superior indoor air quality. A protected air stream which prevents particles from being drawn into suspended ceilings. Uniform treatment of the room thanks to optimised diffusion over 180° or 360° using the Coanda effect. Suitable mixing rate. Local filtration by high efficiency filter medium effective on fine particles up to 2.5 microns. Filter area 10 times greater than the intake grille surface. No discharge from the filter during replacement thanks to the folded filter medium with heat-sealed lateral inserts to make it more rigid. Improved service life compared to a conventional flat filter, thanks to its high retention capacity. Low energy impact. Fire rating: M1. No release of glass fibres. 100% incinerable at end of life.
Options (factory-fitted)
areas (locations close to the sea or with chemical industries located close by) Condensate drain pump Extension Finishing trim frame for STAFF ceilings
Accessories (available separately)
Anti-vibration resilient mounts for mounting brackets. Self-regulating conditioned fresh air inlet module (3 flow rates adjustable using a set of shims). Ø 100-125 mm sleeve adapter Condensate drain pump kit with high safety device. 230 V thermo valve kit. Prewired controller kit mounted on the plate. 80 mm riser kit for gravity drainage without condensate drain pump. Finish counter frame kit for 675 mm suspended ceiling tile. connecting hose kit with or without 9 mm insulation. Fresh air pack: - R1: Fresh air management via presence sensor - R+: Fresh air management via CO2 sensor (max. air flow 90 m3/h recommended, network balancing system not supplied by CIAT) Speed control unit kit for HEE motors with 3-speed on/off control.
Standard wiring diagram without control
2-pipe and 4-pipe application: 7301674 2-pipe + electric application: 7301675
Securing the device
Open mounting brackets, factory-fitted, made from galvanised steel, 15/10th thick, with check valve for securing the threaded rods during fitting and levelling.
Packaging
Strapped cardboard crate for the casing. Fitting template and direction of fitting printed on the cardboard. Visual return/supply air interface supplied separately in protective cardboard packaging. Delivered on film wrapped pallet from the factory.
Controls
RTR-E electromechanical thermostat range V30 electronic range V300 electronic range V3000 networked electronic range (KNX) V-LON networked electronic range (LON)
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.01 A
339
COADIS LINE 600
4
Comfort units COANDA effect cassette