Water-cooled chillers
ELECTRICAL
LW HE Power circuit Nominal power supply Voltage range Control circuit
DATA, HIGH EFFICIENCY UNITS
1328 V-ph-Hz V 1528 1928 2128 2328 2628 400-3-50 360-440 24 V via the built-in transformer A 414 414 0.88 0.90 % 0 135 A 144 217 414 414 0.89 0.90 0 151 162 242 260 587 587 0.88 0.90 0 184 193 295 304 587 587 0.89 0.91 0 200 214 317 340 587 587 0.90 0.92 0 223 232 351 358 207 414 414 556 414 414 631 0.86 0.89 0 134 134 267 144 144 288 217 217 434 230 230 460 118 118 235 191 191 382 414 414 574 414 414 656 0.87 0.90 0 151 151 301 162 162 324 242 242 484 260 260 520 133 133 265 212 212 424 587 414 747 587 414 829 0.88 0.90 0 184 151 334 193 162 355 295 242 537 304 260 564 173 133 305 278 212 490 587 587 780 587 587 882 0.88 0.90 0 184 184 367 193 193 386 295 295 590 304 304 608 173 173 346 278 278 556 587 587 801 587 587 904 0.89 0.91 0 200 200 399 214 214 427 317 317 634 340 340 680 183 183 365 290 290 580 587 587 819 587 587 938 0.90 0.92 0 223 223 447 232 232 464 351 351 702 358 358 716 207 207 414 325 325 650 3028 3428 3828 4228 4628
Nominal start-up current* Circuit A Circuit B A Single power connection A point option Maximum start-up current** Circuit A Circuit B Single power connection point option Cosine phi Nominal*** Total harmonic distortion**** Maximum power input† Circuit A Circuit B Single power connection point option Nominal current drawn*** Circuit A Circuit B A Single power connection A point option Maximum current drawn (Un)† Circuit A A A A A
Circuit B A Single power connection A point option Maximum current drawn (Un -10%)**** Circuit A A 230
Circuit B A Single power connection A point option Maximum power input with Condensing temperature limitation option † Circuit A 118 133 173 183
Circuit B Single power connection point option Maximum current drawn (Un) with Condensing temperature limitation option † Circuit A Circuit B Single power connection point option
*
A A A
191 -
212 -
278 -
290 -
325 -
Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained at standard Eurovent unit operating conditions: evaporator entering/leaving water temperature = 12°C/7°C, condenser entering/leaving water temperature = 30°C/35°C. ** Instantaneous start-up current (maximum operating current of the smallest compressor(s) + locked rotor current or reduced start-up current of the largest compressor). Values obtained at operation with maximum unit power input. *** Values obtained at standard Eurovent unit operating conditions: evaporator entering/leaving water temperature = 12°C/7°C, condenser entering/leaving water temperature = 30°C/35°C **** Values obtained at operation with maximum unit power input. † Values obtained at operation with maximum unit power input. Values given on the unit name plate.