Roof top
SPACE PF 415 - 1200
Burner models: technical characteristics Type of equipment PIN. NOx Class Val Range Thermal output (Hi) kW Useful thermal output kW (L.C.V.) % Heater Performance
Hs Performance (H.C.V.) %
PCH034
PCH045
PCH065
PCH130 (2 X PCH065) B23P - B53P - C13 - C43 - C53 - C63 - C83 PCH080 PCH105 0694CP1457 5
PCH160 (2 X PCH080)
PCH210 (2 X PCH105)
Min. 7,60 8,13
Max. 34,85 33,56
Min. 8,50 8,97
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
42,00 12,40 65,00 16,40 82,00 21,00 100,00 12,40 130,00 16,40 164,00 21,00 200,00 40,45 13,40 62,93 17,77 80,03 22,77 97,15 13,40 125,86 17,77 160,06 22,77 194,30
106,97 96,30 105,50 96,30 108,06 96,82 108,35 97,60 108,40 97,15 108,06 96,82 108,35 97,60 108,40 97,15 96,37 86,76 95,07 86,76 97,36 87,22 97,62 87,93 97,68 87,52 97,36 87,22 97,62 87,93 97,68 87,52 0,6 3,7 0,5 3,7 0,2 3,2 0,3 2,4 0,2 2,8 0,2 3,2 0,3 2,4 0,2 2,8
Flue losses with burner off (Hi) % Flue losses with burner off (Hi) % Losses in enclosure Max. Condensation l/h Carbon monoxide - C0 ppm (0% of O2) Nitrogen oxides - NOx (0% of O2) Available pressure at Power supply Power input
< 0,1 0% 0,9 1,1 2,1 3,3 <5 42 mg/kWh 24 ppm 90 11 74 15 33 mg/kWh 19 ppm 100 65 15 97 40 123 <5 IP X5D from -15ºC to +40ºC UNI/ISO 7/1 - G3/4” 80/80 UNI/ISO 7/1 - G1” UNI/ISO 228/1 - G 1½” 2 X 80/80 20 130 39 mg/kWh 22 ppm 32 mg/kWh -18 ppm 41 mg/kWh -23 ppm 120 230 Vac - 50 Hz single-phase 30 194 80 246 40 260 39 mg/kWh -22 ppm 32 mg/kWh -18 ppm 41 mg/kWh -23 ppm 2,7 4,2 6,6 5,4
Exhaust gases - Polluting emissions
Electrical data
Power input in stand-by Ingress protection rating
Operating Temperatures
Connections
Ø gas connection GAS
Ø intake/exhaust pipes mm
Models PCH034 and PCH045 available only in SPACE PF 90 - 360. Enclosure losses match those of the machine housing the PCH. Max. condensation produced acquired from testing 30%Qn. Value referenced to cat. H (G20) Weighted value to EN1020 ref. to class H (G20), referred to Hi (L.C.V.).
The following table indicates the pressure drop (mmWC) at the burners available for each model:
SPACE PF 420 485 540 600 650 720 840 960 1100 1200 Pressure drop (mm w.c.) (m3/h) 18.000 18.200 20.400 24.000 27.500 30.000 33.000 37.000 42.000 46.000 PCH034 PCH045 PCH065 13,8 14 16,9 PCH080 10,8 11 13,4 13,5 17,1 19,8 17,1 20,8 PCH105 10 10,2 12,4 13 12,6 14,6 12,6 15,3 PCH130 8,8 9 11,6 16,6 10,7 13 9,8 12,6 8,8 10,8 PCH160 6 6,2 7,9 11,3 10,9 13,1 10,9 13,9 11,3 13,7 PCH210 5,6 5,7 7,3 10,3 10,3 12,4 15,2 19,4 12,4 15,1
The following table indicates the type of gas used by the gas burner as a function of the destination country:
Country Austria, Switzerland Belgium < 70kW Belgium > 70kW Germany Denmark, Finland, Greece, Sweden, Norway, Italy, Czech Republic, Estonia, Lithuania, Slovenia, Albania, Macedonia, Bulgaria, Romania, Croatia, Turkey Spain, United Kingdom, Ireland, Portugal, Slovakia France Luxembourg Netherlands Hungary Cyprus, Malta Latvia Iceland Poland Russia Category
II2H3B/P I2E(S)B,I3P I2E(R)B,I3P II2ELL3B/P II2H3B/P II2H3P II2Esi3P II2E3P II2L3B/P II2HS3B/P I3B/P I2H I3P II2E3B/P II2H3B/P
Gas
G20 G20/G25 G20/G25 G20 G20 G20 G20/G25 G20/G25 G25 -G20 -G20
Pressure (mbar) Gas
20 20/25 20/25 20 20 20 20/25 20 25 -20 -20 G31 G31 G31
Pressure (mbar)
37 37
G30/G31 50
G30/G31 50 G30/G31 30 G31 G31 G31 37 37 37/50
G30/G31 50 G30/G31 30 G30/G31 30 37
G20/G25.1 25
G20/G2.350 20/13
G30/G31 37 G30/G31 30