references
Air handling unit
Plug & Play AHU with onboard control, Energy class A+ across the entire range, High efficiency heat recovery unit, EC fan motor assembly, high performance
Specifications Mechanical strength Airtightness Filter bypass leak Thermal transmission Thermal bridge Class D2 L2 F9 T3 TB2
Air flow:
500 to 18 000 m3/h
USE
The FLOWAY dual-flow air handling unit is a PLUG & PLAY ventilation unit equipped with a highly efficient heat recovery unit with plug fans and high performance EC motors, designed to meet all the requirements of recent ecodesign regulations. Unit supplied ready to use, prewired, preprogrammed in the factory and supplied with a remote control. It draws clean, fresh air indoors using, on average, 80% less energy than that needed for air conditioning (cooling and heating). These units are designed for use in the following applications: • Administrative buildings, Offices • Education facilities, Libraries, Community centres • Cafés, Hotels, Restaurants • Shopping Centres • Nursing homes, Healthcare facilities • Collective housing All facilities where ventilation is required. Classic RHE model: 9 sizes, air flow from 300 to 18,000 m3/h. Access RHE model: 5 sizes, air flow from 350 to 8500m³/h. Classic model: 5 sizes, air flow from 300 to 6600 m3/h. Ground installation, horizontal position, horizontal air flow, air circuits on the sides. Vertical model: 3 sizes, air flow from 300 to 2600 m3/h. Ground installation, vertical position, vertical air flow, air circuits on the top. Ceiling-mounted model: 3 sizes, air flow from 300 to 1900 m3/h. Ceiling-mounted horizontal unit with vertical air flows and air connections on the sides.
High energy-efficiency heat recovery unit Depending on its layout, the Floway offers two different high-efficiency heat recovery systems: "CONTRA FLOW" plate heat exchanger equipped with a bypass (Classic, Vertical, Ceiling-mounted models) Rotary heat exchanger (Classic and Access RHE models) Year-round optimal heat recovery unit
RANGE
FLOWAY Classic & Classic RHE
MODELS 1000 2000 3000 4000 5000 6000 7500 10000 15000 MODELS 1000 2000 3000 5000 7500 Nominal flow rate (m3/h)
1000 2000 3000 4000 5000 6000 7500 10000 15000
Max. power* (kW)
1,43 2,50 3,82 4,23 4,23 6,03 6,03 12,06 15,45
Max current* (A)
6,2 3,6 5,5 6,1 6,1 8,7 8,7 17,4 22,3
Voltage (V)
1-Ph 230
3-Ph 400
FLOWAY Access RHE
Nominal flow rate (m3/h)
1000 2000 3000 5000 7500
Max. power* (kW)
1,2 2,5 4,2 6,1 7,1
Max current* (A)
5,4 2,9 6,1 8,8 10,3
Voltage (V)
1-Ph 230 3-Ph 400
FLOWAY Vertical
MODELS 700 1500 2000
Nominal flow rate (m3/h)
1000 1500 2000
Max. power* (kW)
1,43 2,50 2,50
Max current* (A)
6,2 3,6 3,6
Voltage (V)
1-Ph 230 3-Ph 400
FLOWAY Ceiling-mounted
MODELS Nominal flow rate (m3/h) Max. power* (kW) Max current* (A) 700 1,43 6,2 700 1200 1200 1,43 6,2 1600 1600 2,50 3,6 * These values are provided for guidance only and are based on a standard dual-flow unit without electric heater option.
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.01 A
Voltage (V)
1-Ph 230 3-Ph 400
457
FLOWAY