Comfort Unit Controls
AIR-RECIRCULATION
UNITS ONLY
VALVE KIT
COADIS LINE 600 - MAJOR LINE - MELODY2
230 / 1 / 50 VALVE KIT - Fittings not included 1 electrothermic two-way valve PN 16 - DN 15 - KVS 1.6 max. 1 electrothermic four-way valve* PN 16 - DN 15 - KVS 1.6 max. 1 electrothermic two-way valve PN 16 - DN 15 - KVS 1.6 max.
Thermostats 2-pipe system
Heating-only or cooling-only 3 ventilation speeds RTR-E 7011 room thermostat Heating/cooling 3 ventilation speeds - Manual summer/winter toggle switch RTR-E 7012 room thermostat - RTR-E 7203 room thermostat with automatic changeover (on four-way valve only)
COADIS LINE 600 612, 622, 632 MAJOR LINE 102, 202, 302, 402A, 402C, 502A MAJOR LINE 102, 202, 302, 402A, 402C, MAJOR LINE 402B, 402D, 502B, 502C, 502D, 602
Code Code Code Code Code
7301640 7301641 7245718 7245719 7245720
Code 5201018
Code 5201024
1 electrothermic four-way valve* PN 16 - DN 15 - KVS 1.6 max.
Code
5201021 + 7128892
Code
7245721
2-pipe cooling system with electric battery (1)
Manual summer/winter toggle switch 3 ventilation speeds RTR-E 7012 room thermostat with manual summer/winter toggle switch (Power cons. 1400W) (2) Operation with neutral zone 3 ventilation speeds RTR-E 7203 room thermostat with neutral zone Code 5201021 (Power cons. 1400W) (2) Optional two-contact 230V relay 16A - factory-fitted (3)
1 electrothermic two-way valve PN 16 - DN 20 - KVS 2.5 max. 1 electrothermic four-way valve PN 16 - DN 20 - KVS 2.5 max. 1 electrothermic two-way valve PN 16 - DN 25 - KVS 4.5 max. 1 electrothermic four-way valve PN 16 - DN 25 - KVS 4.5 max.
MELODY2 61,62,63
Code
7469216
Code 5201024
MELODY2 61,62,63
Code
7469217
MELODY2 92,93,94
Code
7469214
MELODY2 92,93,94
Code
7469215
Code E038806
4-pipe system
2 electrothermic two-way valves PN 16 - DN 15 - KVS 1.6 max. 2 electrothermic four-way valves* PN 16 - DN 15 - KVS 1.6 max. 2 electrothermic two-way valves PN 16 - DN 15 - KVS 1.6 max. 2 electrothermic four-way valves PN 16 - DN 15 - KVS 1.6 max. 2 electrothermic two-way valves PN 16 - heating DN 15 - cooling DN 20 KVS 2.5 max. 2 electrothermic four-way valves* PN 16 - heating DN 15 - cooling DN 20 - KVS 2.5 max. 1 electrothermic two-way valve PN 16 - DN 20 - KVS 2.5 max. 1 electrothermic two-way valve PN 16 - heating DN 15 - KVS 1.6 max. 1 electrothermic four-way valve PN 16 - DN 20 - KVS 2.5 max. 1 electrothermic four-way valve PN 16 - heating DN 15 - KVS 1.6 max. 1 electrothermic two-way valve PN 16 - DN 25 - KVS 4.5 max. 1 electrothermic two-way valve PN 16 - heating DN 20 - KVS 2.5 max. 1 electrothermic four-way valve PN 16 - DN 25 - KVS 4.5 max. 1 electrothermic four-way valve PN 16 - heating DN 20 - KVS 2.5 max.
Code
COADIS LINE 600 624, 634
E046500
1 ventilation speed RTR-E 7201 room thermostat with neutral zone 3 ventilation speeds RTR-E 7203 room thermostat with neutral zone
Code 5201025
Code Code Code Code
MAJOR LINE 404Y, 504, 604
E046501
Code 5201021
MAJOR LINE 104, 204, 304, 404X
7245722 * Three-way valve(s) with bypass. 7245723 7245724 7245725 7469216 7301640 7469217 7301641 7469214 7469216 7469215 7469217
* * Refer to instruction manuals for information on the maximum allowable differential pressures and the maximum operating pressures based on the KVS of the valve used.
(1) MAJOR LINE: 2-pipe setup + electric battery with one resistor only. (2) A relay (optional extra or supplied by the customer) is required for higher capacities. (3) Excl. Coadis Line and Melody2: CDL600: Max. power 1200W CDL900 and Melody 2: Relay included with the base unit
Code Code
In stock
MELODY2 61,62,63
Code Code
MELODY2 61,62,63
Code Code
MELODY2 92,93,94
Code Code
MELODY2 92,93,94
Code