Water chillers and air-to-water heat pumps
STD VERSION: TECHNICAL CHARACTERISTICS WITH PUMP INCLUDED LPC / ILPC
CIATCooler LPC / ILPC
Cooling ESEER SCOP Prated (kW) SCOP Prated (kW) Indoor 3/h)
90VSTD
2.67 3.24 126% 16.83 3.82 150% 12.77 3.1 3.1
100VSTD
2.61 3.13 122% 19.20 3.60 141% 14.71 3.7 4.2
120VSTD
2.89 3.10 121% 21.83 3.60 141% 16.72 4.3 3.8 12
160VSTD
2.97 2.95 115% 26.21 3.44 135% 24.22 5.7 6.2
180VSTD
2.84 3.06 119% 30.53 3.57 140% 27.28 6.2 4.5 1.5
200VSTD
2.73 2.96 115% 38.31 3.35 131% 34.73 7.5 4.9
240VSTD
2.99 3.10 121% 41.45 3.74 147% 39.27 8.5 4.1
280VSTD
2.99 2.95 115% 44.73 3.56 139% 42.59 9.6 5.1 20
320VSTD
3.29 2.96 115% 51.02 3.55 139% 46.95 11.7 3.5
360VSTD
3.17 3.02 118% 65.65 3.40 133% 58.15 12.8 4.3
Heating
vessel
2) 100 Water 40ºC (l) 700 410 3/4” M Voltage (standard) LPC / ILPC 1117 1000 860 1447 LPC / ILPC 318 335 139 242 328 345 139 242 390 410 161 315 1398 1000 860 1727 408 428 161 315 408 429 161 315 of the installation Water 50ºC (l) 150 650 360
225 1100 625 1” M 230 V / I ph 1 kW (4.3 A) 2113 1000 860 1447 586 622 161 393 666 702 169 404 700 736 169 404 2673 1000 860 1727 736 774 169 404 741 780 169 404
(LPC / ILPC
Weight
CIATCooler LPC / ILPC
Cooling ESEER SCOP Prated (kW) SCOP Prated (kW) Indoor 3/h)
420VSTD
3.13 2.95 115% 82.76 3.29 129% 70.59 15.3 7.5
480VSTD
3.07 3.04 119% 90.84 3.61 141% 77.41 16.7 8.8 35
600VSTD
3.02 3.09 120% 111.30 3.34 131% 95.09 20.5 11.1
640VSTD
3.00 2.95 115% 118.94 3.42 134% 102.06 23.2 10.8 1.5
720VSTD
2.87 2.95 115% 137.14 3.34 131% 116.45 26.2 13.3 50 275 3035 1840
840VSTD
3.04 3.10 121% 159.98 3.46 135% 137.01 30.5 12.9
960VSTD
2.89 3.21 126% 175.15 3.68 144% 148.68 33.1 15.1
Heating
vessel
2) 275 Water 40ºC (l) 2050 1210 of the installation Water 50ºC (l) Voltage (standard) LPC / ILPC 3400 1000 900 1970 LPC / ILPC 1107 1169 202 486 1183 1246 202 486 1272 1336 202 486
375 2985 1790
(LPC / ILPC
1” M 230 V / I ph 1 kW (4.3 A) 3600 1000 1150 1970 1512 1592 241 544 1523 1603 241 544 2038 2131 263 668 4500 1000 1200 1970 2189 2282 263 668
Weight
Values calculated in accordance with the EN-14825-2013 standard given for bivalente temperature of -5ºC in average climate and 2ºC in warmer climate. The water capacity for the installation indicated in this table corresponds to the maximum that the installation allows based on the expansion vessel assembled on the unit. The volume of the buffer tank has been taken into account for this section. In case the capacity of the installation is greater, it is necessary to add a supplementary expansion vessel to the installation based on its volume. This temperature corresponds to the temperature that the circuit may reach when the unit is stopped. This case must be considered for cooling-only units. This temperature corresponds to the maximum temperature that the circuit may reach when operating in a heat pump. Minimum distance between the unit and the separte hydraulic module: 167 mm.