Water chillers Heat pump
DYNACIAT LG Cooling C1 C1 C1 C2 C2 C2 C1 Nominal capacity EER EUROVENT class Nominal capacity EER EUROVENT class ESEER
80A 090A 100A 120A 130A 150A 180A 200A 240A 260A 300A 360A 390A 450A 480A 520A 600A kW 25 kW/kW 4.72 B kW 34 kW/kW 6.42 A kW/kW 5.1 29 4.72 B 39 6.1 A 5.09 32 4.69 B 43 6.03 A 5.03 37 4.73 B 50 6.04 A 5.05 42 4.69 B 57 5.9 A 5.03 47 4.72 B 66 6.06 A 5.07 58 4.72 B 79 6.12 A 5.83 63 4.65 B 86 5.93 A 5.87 74 4.69 B 102 6.19 A 5.79 84 4.65 B 113 5.93 A 5.99 95 4.68 B 129 6.13 A 5.93 115 4.79 B 155 6.2 A 6.11 130 4.77 B 176 6.1 A 6.22 144 4.7 B 196 6.01 A 6.15 153 4.83 B 206 6.23 A 6.05 172 4.78 B 231 5.97 A 6.11 192 4.79 B 262 6.14 A 6.02
Full load performances*
Seasonal Heating Full load performances* Seasonal
H1 H1 H1 H1 H1
Nominal capacity COP SCOP hs heating Prated
kW
30
35 5.53 5.45 210 39 69 66
38 5.49 5..36 206 43 69 66
44 5.52 5.4 208 50 69 67
50 5.49 5.35 206 57 70 68
56 5.51 5.38 207 64 70 68
70 5.58 6.12 237 79 72 68
77 5.48 6.08 235 87 72 69
89 5.53 6.09 235 101 72 69
101 5.46 6.11 236 115 73 69
114 5.5 6.09 235 129 73 70
137 5.63 6.31 244 155 76 73
156 5.61 6.37 237 176 77 74
172 5.53 6.29 244 196 78 75
183 5.67 6.31 244 208 76 73
206 5.62 6.32 245 234 77 74
230 5.59 6.18 239 261 78 75
kW/kW 5.53 kW/kW 5.46 % kW/kW dB(A) dB(A) mm mm mm kg 211 34 67 65
Sound levels(1) Standard unit sound power Low Noise (LN) option sound power Dimensions (2) Length Width Height Operating Weight (3) Standard unit Compressors Quantity No. of control stages Refrigerant (3) Number of circuits Load Oil Charge via compressor Control Minimum power Evaporator Water volume Hydraulic connections Diameter Maximum water-side operating pressure Condenser Water volume Hydraulic connections Diameter Maximum water-side operating pressure Casing paint
* ** C1 C2 H1
600 600 600 600 600 600 880 880 880 880 880 880 880 880 880 880 880 1044 1044 1044 1044 1044 1044 1474 1474 1474 1474 1474 1583 1583 1583 1583 1583 1583 901 901 901 901 901 901 901 901 901 901 901 1574 1574 1574 1574 1574 1574 392 403 413 441 707 Hermetic Scroll 48.3 r/s 1 1 1 1 1 1 2 2 2 2 2 3 1 1 1 1 1 1 2 2 2 2 2 3 R410A (GWP=2088) 1 1 1 1 1 1 1 1 1 1 1 1 3.5 3.5 3.6 3.7 4.0 4.6 7.6 7.8 7.9 8.7 11.5 13.3 7.2 7.3 7.4 7.6 8.2 9.5 15.9 16.3 16.5 18.2 24.0 27.8 160SZ 3.0 3.3 3.3 3.3 3.3 3.6 3.3 3.3 3.3 3.3 3.6 3.3 Connect Touch Control 100 100 100 100 100 100 50 50 50 50 50 33 Brazed-plate heat exchanger 3.3 3.6 3.6 4.2 4.6 5 8.4 9.2 9.6 10.4 12.5 15.2 Victaulic 1.5 1.5 1.5 1.5 1.5 1.5 2 2 2 2 2 2 1/2 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Brazed-plate heat exchanger 3.3 3.6 3.6 4.2 4.6 5 8.4 9.2 9.6 10.4 12.5 15.2 Victaulic 1.5 1.5 1.5 1.5 1.5 1.5 2 2 2 2 2 2 1/2 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Colour code RAL 7035 and RAL 7024
(1)
191
200
200
207
212
220
386
733 3 3 1 14.5 30.3 3.3 33 17.4
758 3 3 1 15.6 32.6 3.6 33 19
841 4 4 2 21.0 43.8 3.3 25 23.2
877 4 4 2 23.0 48.0 3.3 25 26.5
908 4 4 2 24.2 50.5 3.6 25 29
kg tCO2e litres % litres inches kPa litres inches kPa
2 1/2 2 1/2 3 3 3 1000 1000 1000 1000 1000 17.4 19 23.2 26.5 29
2 1/2 2 1/2 3 3 3 1000 1000 1000 1000 1000
In accordance with standard EN14511-3:2013. In accordance with standard EN14825:2013, average climate conditions. Conditions in cooling mode: Evaporator water entering/leaving temperature 12°C/7°C, Condenser water entering/leaving temperature 30°C/35°C. Evaporator/condenser fouling factor 0 m2 K/W. Conditions in cooling mode: Evaporator water entering/leaving temperature 23°C/18°C, condenser water entering/leaving temperature 30°C/35°C. Evaporator/condenser fouling factor 0 m2 K/W. Conditions in heating mode: Evaporator water entering/leaving temperature 10°C/7°C, condenser water entering/leaving temperature 30°C/35°C. Evaporator/condenser fouling factor 0 m2 K/W.
(2) (3)