references
SOUND
LEVELS
dB(A)
Measurement conditions: in a free field, measured at a distance of 5 metres, directivity 2 and 1.5 metres from the ground. Note: the sound pressure level depends on the installation conditions, and is therefore only given as a guide. Values obtained in accordance with ISO standard 3744.
SPACE PF 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Total LW dB(A) Total LP dB(A) 90HEE 90T 34.2 47.5 56.3 64.3 70.7 66.1 58.8 47.7 73.0 46.4 120HEE 120T 43.2 56.5 65.3 73.3 79.7 75.1 67.8 56.7 82.0 55.4 160HEE 160T 47.2 60.5 69.3 77.3 83.7 79.1 71.8 60.7 86.0 59.4 180HEE 180T 48.2 61.5 70.3 78.3 84.7 80.1 72.8 61.7 87.0 60.4 200HEE 48.2 61.5 70.3 78.3 84.7 80.1 72.8 61.7 87.0 60.1 240HEE 240T 48.2 61.5 70.3 78.3 84.7 80.1 72.8 61.7 87.0 60.1 320HEE 320T 48.2 61.5 70.3 78.3 84.7 80.1 72.8 61.7 87.0 60.1 360HEE 360T 49.2 62.5 71.3 79.3 85.7 81.1 73.8 62.7 88.0 61.0
ELECTRICAL
Nb. 1 2
CONNECTION
90 to 360 3 wires + ground telephone cable 6 wires standard (RJ12 connector) 2 wires for power supply 230V + 1 shielded cable for communication type AGW20 / 22 (1 braided pair + drainwire + shielding) 2 wires 2 wires 1 wire 2 wires 5 wires 3 wires
Space PF Main power supply 400 III (±10%) Remote connection of pGD1 terminal (by default it’s installed on the electric panel)
3
Connection of TCO user terminal on the electric panel (optional)
4 5 6 7 8 9
Remote off/on (optional) Main failure signal (optional) Circulation pump signal for HWC (antifreeze sec.) (opt.) NTC ambient probe (std) RS485 ambient probe (opt.) Air quality probe (opt.)
In this case, it´s posible to install the TCO terminal on the electric panel. It’s necessary that the terminal uses the same power supply that the control board. Up to four RS485 ambient probes can be connected in series on the field-bus of the control board.
SPECIFICATIONS
SPACE PF
FOR THE SINGLE COMPRESSOR PER CIRCUIT (OPTION)
A single compressor to replace the tandem.
90HEE (l) (A) (kg) 1.6 15.9 -21 200HEE (l) (A) (kg) 2 x 2.7 2 x 14.2 -32 90T 3.0 15.3 -21 ----120HEE 3.0 15.3 -15 240HEE 2 x 3.3 2 x 20.1 -32 120T 3.3 20.1 -15 240T 2 x 3.3 2 x 23.0 -32 160HEE 1/1/1 3.3 21.1 -10 320HEE 2/2/2 2 x 3.3 2 x 23.0 -22 2 x 3.3 2 x 25.1 -22 2 x 3.3 2 x 25.1 -31 2 x 6.2 2 x 29.1 -31 3.3 25.0 -10 320T 3.3 25.0 -21 360HEE 6.2 29.1 -21 360T 160T 180HEE 180T
Number of compressors / Stages / Circuits Oil volume Maximum input current Additional weight SPACE PF Number of compressors / Stages / Circuits Oil volume Maximum input current Additional weight
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.01 A
523
SPACE PF 90 - 360
Roof top