references
Roof top
SPACE PF 90 - 360
SPACE PF Air pressure drop Heating capacity Water 80/60ºC and air intake 20ºC Water pressure drop Heating capacity Water 90/70ºC and air intake 20ºC Water pressure drop Weight (empty) (mmWC) (kW) (m3/h) (mmWC) (kW) (m3/h) (mmWC) (kg) 90HEE 90T 1.8 24.6 1.1 0.7 30.4 1.4 1.0 11.1 120HEE 120T 3.5 31.8 1.4 1.1 39.4 1.8 1.4 11.1 160HEE 160T 3.6 44.0 2.0 1.0 54.6 2.4 1.2 15.1 180HEE 180T 3.9 45.0 2.0 1.0 55.7 2.5 1.2 15.4 200HEE 2.4 96.5 4.3 1.5 119.9 5.3 1.8 34.8 240HEE 240T 3.5 104.0 4.6 1.7 129.0 5.7 2.0 34.8 320HEE 320T 4.6 115.4 5.1 1.6 143.3 6.4 2.5 34.8 360HEE 360T 4.0 140.7 6.2 3.5 172.6 7.7 5.0 41.7
Note: - with a droplet eliminator on the indoor air coil, it is not possible to fit a hot water coil. - this option still incorporates an antifreeze thermostat as a safety feature.
Position of the auxiliary coil hydraulic connections (option)
A (mm) 203 203 295 B (mm) 190 190 250 C (mm) 177 177 177 Ø of hydraulic connections: I/O 1 1/4” 1 1/2” 2”
SPACE PF 90HEE / 90T / 120HEE / 120T 160HEE / 160T / 180HEE / 180T 200HEE / 240HEE / 240T / 320HEE / 320T / 360HEE / 360T
1
C A
2
KEY
1
Water outlet Water inlet
B
2
Note: the I/O connections for the coil are located within the unit. The connection can be made at the base of the unit, using the flexible sleeves, or via the lateral panel. The diagram above shows the location of the pre-punched holes located on the lateral panel. For connections via the base, consult the diagram for the pre-assembled frames.
It is recommended that a droplet eliminator is installed on the indoor coil from the following air flow rates.
SPACE PF (m3/h) 90HEE 90T 7 280 120HEE 120T 7 280 160HEE 160T 10 190 180HEE 180T 10 190 200HEE 14 560 240HEE 240T 14 560 320HEE 320T 14 560 360HEE 360T 17 480
Note: - under operating conditions with a high level of dehumidification in the indoor coil (for example on installations close to the seafront), it may be necessary to install an eliminator even if the flow rate is less than that given above. - with a hot water coil, it is not possible to fit the droplet eliminator.
For the burner characteristics, see the documentation for SPACE PF 415 to 1200. The following table indicates the pressure drop (mWC) at the burners available for each model:
Nominal air 3/h) 4 000 6 000 8 700 9 000 10 000 12 000 14 300 15 900 Pressure drop (mmWC) PCH034 3.4 6.6 12.2 12.9 ----PCH045 ----9.8 13.3 --PCH065 ----8.4 11.4 12.2 14.5 PCH080 ----5.1 6.9 9.2 11.0
SPACE PF 90HEE / 90T 120HEE / 120T 160HEE / 160T 180HEE / 180T 200HEE 240HEE / 240T 320HEE / 320T 360HEE / 360T