references
Compact air-air rooftop units
PJ range
Up to 3 values of total power available for each model: These units can be supplied for the following power supply voltages: 400 V / 3 ph + N / 50 Hz (standard) 400 V / 3 ph / 50 Hz (option)
PJ range 0090 to 0120 0140 to 0190 0200 to 0280 E0L (Low)
9 kW 9 kW 18 kW
E0N (Nominal)
18 kW 18 kW 27 kW
E0H (High)
not available 27 kW 36 kW
Outdoor coil and/or indoor coil (and hot water coil) with copper tubes and copper fins. Outdoor coil and/or indoor coil (and hot water coil) with copper tubes and fins of an aluminium alloy (INERA®), of high performance and great resistance to the corrosion. Outdoor coil and/or indoor coil (and hot water coil) with copper tubes and aluminium fins with polyurethane coating. Outdoor coil and/or indoor coil (and hot water coil) with copper tubes and aluminium fins with Blygold® coating.
Auxiliary hot water coil, with three-way valve and proportional control, for assembly inside the unit. There are two configuration types available: • Standard (B0S), this option always incorporates an antifreeze thermostat as a safety device. Consult for percentages of glycol water above 20%. • Great Cold (B0C), with anti-freeze technology based on the water temperature. This protection is made up of a circulation pump, two sensors inserted in the input and the output of the coil, as well as an electrical heating for the piping layout.. Important: this option is mandatory for an outdoor temperature lower than -20ºC WB. Gas boiler + Auxiliary hot water coil. The circuit of the auxilary water coil (installed inside the unit) is connected to the gas boiler.
Natural or propane gas burner with modulating actuator, in accordance with the Gas Directive 2009/142/EC, installed into a pre-assemby roofcurb (optionally supplied with the unit). Condensation boiler with premixing and modulation technology that allows outputs close to 109% with regard to the lower heating value (LHV).
PJ range 0090 to 0190 0200 to 0240 0280 to 0380 020 Model of PCH burner 034 045 065 080 080 105
Note: It is recommended to use the clogged filter detection and anti-freeze protection options for the components of the electrical cabinet when outdoor temperatures are low (compulsory if the outdoor temperature is lower than -10ºC WB).
Anti-freeze protection kit for low temperatures (<-10ºC). This kit is mandatory for an outdoor temperature lower than -10ºC WB. • Electrical heater for protection of the components of the electrical cabinet. • Compressor with protection for low temperature. • Dampers of the mixing box with spring for automatic closing in case of a power failure. • Electrical heater for anti-freeze protection of dampers of the mixing box. Anti-freeze protection kit for low temperatures (<-14ºC). This kit is mandatory for an outdoor temperature lower than -14ºC WB. • Reinforced electrical heater for protection components of the electrical cabinet.
Gas burner Pre-assemby roofcurb
of
the
• Compressor with protection for low temperature. • Dampers of the mixing box with spring for automatic closing in case of a tension cut. • Electrical heater for anti-freeze protection of dampers of the mixing box.
Auxiliary electrical heaters, with two power stages and on/ off control, for assembly and connection inside the unit.
502