references
SPACE PF (m3/h) Available static pressure Nominal power input Number/ Number of impellers Power Speed Maximum input current Additional weight (MC1) (kW) (rpm) (A) (kg) (mmWC) (kW)
90HEE 90T 4 000 10.0 0.30
120HEE 120T 6 000 10.0 0.70
160HEE 160T 8 700 10.0 1.04
180HEE 180T 9 000 10.0 1.13 1/1
200HEE 10 000 12.5 1.13
240HEE 240T 12 000 12.5 1.43
320HEE 320T 14 300 12.5 2.14
360HEE 360T 15 900 12.5 2.76
0.55 585 1.6 -33
1.1 671 2.7 -25
1.5 583 3.6 -11
1.5 593 3.6 -11
1.5 477 3.6 -35
2.2 503 5.0 -35
3 547 6.9 -26
4 581 9.0 -16
SPACE PF (m3/h) Rated available static pressure Nominal power input Maximum available static pressure Quantity x Diameter Capacity Speed Maximum input current (mmWC) (kW) (mmWC) (mm) (kW) (rpm) (A)
90HEE 90T 4 000 12.0 0.31 98.7
120HEE 6 000 12.0 0.66 90.1
120T
160HEE 160T 8 700
180HEE 180T 9 000 15.0 1.54 52.1
200HEE 10 000 20.0 1.28 93.9
240HEE 240T 12 000 20.0 1.76 90.1
320HEE
320T
360HEE 360T 15 900
14 300 20.0 2.34 79.0 2 x 500 2 x 2.68 2 x 1700 8.4 25.0 2.60
15.0 0.73
15.0 1.42 57.7
25.0 3.20 68.9
1 x 500 2.68 1 700 4.2
MRC refrigerating recovery circuit
SPACE PF (m3/h) Plug fan Maximum avail. static (MRC0/MRC1 assemblies) pressure on the return Centrifugal fan (MRC1 assembly) Avail. static pressure on the return Additional weight Type Recovery compressor characteristics Number of compressors / Circuits Oil type Oil volume Maximum input current R410A refrigerant Load Environmental impact (l) (A) (kg) (tCO2eq) 2.6 5.4 1.1 6.3 2.7 5.6 3.3 6.9 (mmWC) (mmWC) (kg) 90HEE 90T 4 000 96.4 10.0 -33 120HEE 120T 6 000 85.9 10.0 -25 160HEE 160T 8 700 50.3 10.0 -11 180HEE 180T 9 000 44.3 10.0 -11 Scroll 1/1 Copeland 3MAF (32 cST). Danfoss POE 160SZ. ICI Emkarate RL 32 CF. Mobil EAL Arctic 22CC 1.6 9.0 3.3 6.9 6.1 12.7 6.1 12.7 3.0 15.3 6.1 12.7 6.2 12.9 200HEE 10 000 84.8 10.0 -35 240HEE 240T 12 000 81.0 12.5 -35 320HEE 320T 14 300 69.1 12.5 -26 360HEE 360T 15 900 58.3 12.5 -16
Important: With this option, CIATrtc electronic control is mandatory.
2-stage auxiliary electric heaters for assembly and connection within the unit. Not available for models 90 to 180 with upper supply air.
SPACE PF Total power (kW) Stage power (kW) 90HEE / 90T / 120HEE / 120T Current (A) (400V / 3-ph / 50Hz) 160HEE / 160T / 180HEE / 180T 200HEE / 240HEE / 240T / 320HEE / 320T 360HEE Module weight (kg) 12 6+6 17.3 17.3 Unavailable Unavailable 11 18 9+9 26.0 26.0 26.0 26.0 15 39.0 39.0 39.0 19 52.0 52.0 24 27 9 + 18 36 18 + 18 Unavailable Unavailable Unavailable 65.0 29 45 18 + 27
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.01 A
525
SPACE PF 90 - 360