Water loop roof top unit
High capacity supply air and return air fan available. Overpressure control with MC0 and MC1 assemblies. Pre-assembled standardised frames made from galvanised sheet steel with thermal insulation. Adjustable height.
Ambient temperature probe with RS485 communication. By default the control incorporates a NTC probe. Note: An ambient probe with RS485 communication is required for installation to more than 30 m. Adaptation frames on the ground. for the replacement of units Two to four ambient temperature probe with RS485 communication. Ambient T+RH probe with RS485 (compulsory in units with enthalpic or thermoenthalpic free-cooling as ptional). In this case also added outdoor air humidity probe. Change to AVANT+ electronic control with TCO terminal as standard and pGD1 terminal as optional (available for all models): this control does not manage cooling recovery circuit, plug-fan, gas burner, energy meter, air quality sensor, smoke detector or refrigerant leak detecto. Communications The CIATrtc control allows communication to be established with a centralised management system using a specific BMS card for one of the following communication protocols: RS485 serial cards for communication using the Carel, ModBus, LonWorks®, BACnetTM MSTP and Konnex protocols. The pCOWEB Ethernet card for communication using the ModBus TCP/IP, BACnetTM Ethernet, TCP/IP, SNMP V1-2-3, FTP and HTTP protocols. Supervision solutions See the supervision section
Rubber anti-vibration mounts.
Power supply with neutral. Electric energy consumption. meter to monitor the installation's
Energy meter and calculation of the cooling and heating capacities. High performance phase monitoring relay Marked electrical cables. Numbered components in the electrical cabinet.
Soft start for the supply air fan and/or return air fan, increasing the warm-up time, mainly intended for installations with textile ducting. Required for motors of 15 kW and above. Differential pressure switch to detect fouled filters. Differential pressure switch for checking the air flow. Smoke detection unit compliant with the NF S 61-961 standard. Refrigerant leak detector
SEI4C seaworthy packaging. Skids for transport in a closed container (except for MC1 and MRC1 assemblies).
(1 unit)
System start-up and 1-year warranty extension, including parts, labour and movement. System start-up and 2-year warranty extension, including parts, labour and movement.
(10 units)
TCO user terminal, for installation on the electric panel, instead of pGD1 terminal. Control without pGD1 terminal (for units with shared terminal). Remote control kit for up to 200 m from the pGD1 terminal (pGD1 terminal + 2 TCONN cards).
(300 units)