references
Comfort units COANDA effect cassette
COADIS LINE 600
TECHNICAL
DESCRIPTION
Return/supply air interface
VISUAL interfaces: Coanda effect diffusion via a single narrow opening vent and specific internal profile. 2 models available: Visual 180°or 360°, In sheet metal painted in RAL 9010 to be fitted over the chassis and exactly the same dimensions as a standard suspended ceiling tile. Micro-perforated hinge-mounted metal return air grille with housing for EPURE function filter, opens fully without tools. PSE insulation, M1 fire resistance with very low heat transfer coefficient.
Condensate drain pan
Single unit main pan in high-density sealed PSE for use in all climates, naturally sloped and removable from below without the need to open the suspended ceiling. Fire rating: M1. ABS PC auxiliary pan with no water retention provided as an accessory for the recovery of condensates from the valves and coming from the main pan. Gravity drain: height 70 mm. Drainage bushing: external Ø 15 to 20 mm.
Base
Fan motor assembly
Low energy motor making it possible to reduce electrical consumption by up to 85%. offering more linear torque progression and a lower operating sound level than BLDC (Brushless Direct Current) technology.
Single casing and reduced size for all unit sizes, fits in place of a 600 x 600 mm or 675 x 675 mm suspended ceiling tile (option). Reduced weight compared to the previous generation cassette. Ribbed galvanised steel motor support base panel, 10/10th thick. High-density PSE casing integrating thermal and acoustic functionalities. 15 mm thick for the base and 25 mm to 30 mm thick for the vertical walls which form the casing. Low emission of TVOCs and no halogenated compounds. ABS corner reinforcements fitted with open galvanised oneway steel mounting brackets for assembly of threaded rods. Fire rating: M1. Hydraulic, air and electrical connections on the same side of the technical panel at the rear of the unit providing a single access point. Finish frame in RAL 9010 galvanised steel, 8/10th thick, housing the diffusion interface. Centring of the unit between the suspended ceiling profiles using anti-vibration elastomer mounts fitted on the finish frame.
HEE motor
without expansion board.
winding. alarm feedback via a Konnex protocol communication bus (via the V3000 controller).
Note: The minimum voltage required for start-up of the motor is 2V.
Water coil
Or Asynchronous motor
1 hot water or cold water circuit (2-pipe system) 1 hot water + 1 cold water circuit (4-pipe system) Single piece sleeve with 40 mm centre to centre distance with integrated sealed flush fitting female revolving unions, for easy fitting of the control valves.
5 factory-wired speeds connected to a terminal strip for customisation.
winding.
Fan(s)
- 4-pipe application: 80°C, - 2-pipe application: 70°C, - 2-pipe/2-wire application: 55°C (min air flow rate: 200m3/h). Min. cold water inlet temperature: 6°C
Electrics box
keep it open and screw closure.
Electric heater (2-pipe + electric system)
230/1/50 single-pipe electrical elements inserted into the aluminium housing. 2 temperature limiters, manually and automatically reset, inserted in the aluminium block with easy access that does not require the suspended ceiling to be opened, via the Intake / outlet interface. Heating element supply connected to the terminal block inside the electrics box. It is possible to deactivate a heater element on site by means of a shunt on the terminal to reduce the electrical power.
EN 50022, 7.5 mm deep. 0.5 to 2.5 mm² - Max current: 24A – Shock resistance: 8 kV. Cable routing for customer connections.
Fresh air supply sleeve
Ø100 mm fresh air supply connection sleeve integrated in the casing with removable plug.
338
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.01 A