references
Axial air heaters
ALL-ELECTRIC HELIOTHERME CONTROL (diagram in Eco+ ELEC BOX user manual)
Eco+ ELEC BOX range
Figure F
Slave unit
Master controller
TECHNICAL SPECIFICATIONS OF THE DIFFERENT CONTROLLERS
HELIOTHERME or TPL CONTROL AND ACCESSORIES
CONTROL Figure HEE Mono Box A Function Number of heliotherms or TPL that can be controlled Protection rating Weekly timer (Comfort/ECO/frost protection) Supply Voltage/Phase/Frequency Electrical protection (circuit breakers, connectors, disconnectors) Air control Water control Integrated temperature sensor Remote on/off switch and fault summary MODBUS/LON and BACnet IP communication Fresh air control 1 to 6 54 INCLUDED 230 V/1/50Hz INCLUDED Proportional 0 - 10V Proportional 0 - 10V INCLUDED INCLUDED OPTION YES Accessories BOX CONTROL Slave unit for Eco+ 3-PH BOX BMR Eco+ 3-PH BOX Multiple connection unit (controls max. 3 units) Eco+ ELEC BOX slave unit - 9.6 KW (for H4350 TE 3-PH) Eco+ ELEC BOX slave unit - 18.9 KW (for H4400 TE 3-PH) Eco+ ELEC BOX slave unit - 28.8 KW (for H4500 TE 3-PH) Eco+ ELEC BOX slave unit - 43.2 KW (for H4500 TE 3-PH) ½ " valve kit KV 1.6 (H4300) ¾ " valve kit – KV 2.5 (H4351-4352-4401-4451) ¾ “ valve kit – KV 4 (H4353-4402-4403-4452-4501) 1“ ½ valve kit – KV 6.3 (H4453-4502-4503-4631) 1“ ½ valve kit – KV 10 (H4632-4633) 220/24 Vac safety transformer (required for the electrical feed of the valve servomotor(s) (010V) Change-over switch thermostat (for automatic Summer-Winter change-over) Padlockable proximity switch 6P for 3-PH Eco+ BOX Padlockable proximity switch 3P for MONO or HEE Eco+ Box Remote sensor Fresh air kit (includes a damper servomotor and a frost protection thermostat) 0596142 7462538 B400414 0596142 7207381 B400414 INCLUDED 7435107 7128892 0596147 INCLUDED INCLUDED B403210 B400410 B400411 B400412 B400413 INCLUDED INCLUDED 7391284 7184939 7219774 7218912 7239492 7218907 7218908 7218910 7218911 7219774 7218912 7219774 1 to 3 55 INCLUDED 230 V/1/50Hz TO BE FITTED Proportional 110 - 230V Proportional 0 - 10V INCLUDED NOT INCLUDED NO NO 1 to 9 55 INCLUDED 400 V/3/50Hz+N INCLUDED 2-speed LS/HS Proportional 0 - 10V INCLUDED NOT INCLUDED NO NO 1 to 3 55 INCLUDED 400 V/3/50Hz+N INCLUDED 2-speed LS/HS Proportional 0 - 10V INCLUDED NOT INCLUDED NO YES INCLUDED NOT INCLUDED NO NO 1 to 3 55 INCLUDED 400 V/3/50Hz+N INCLUDED 1 speed LS or HS 1-Ph ECO+ BOX unit B 3-PH ECO + BOX with BMR C and D 3-PH ECO + BOX with fresh air control E ECO + ELEC BOX F
HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 17.01 A
637
HELIOTHERME 4000
7