references
Enfriadora y bomba de calor reversible inverter aire-agua
Ereba 17-21
DEMANDA DE POTENCIA FRIGORÍFICA DE ACUERDO CON LA NORMA EN14511-3
Ereba Reversible
TEMPERATURA DEL AIRE EXTERIOR EN °C Temperatura del agua de salida en °C EREBA Reversible Nom. 5 7 10 15 18 17HT 21HT 17HT 21HT 17HT 21HT 17HT 21HT 17HT 21HT 5 Pf kW Máx. Nom. 3.0 4.2 3.0 4.4 3.2 4.6 3.4 4.7 3.5 5.0 2.7 3.0 2.7 3.0 1.1 3.1 1.1 3.2 1.2 3.3 15.7 13.3 15.7 20.9 14.4 24.5 16.6 14.1 16.6 22.0 15.2 26.4 18.0 20.6 22.2 7.9 8.5 9.1 18.0 20.6 22.2 23.8 16.5 29.0 27.5 18.8 33.3 29.5 20.3 36.3 Pa kW Máx. Nom. 3.0 6.3 3.0 6.3 3.2 6.4 3.4 6.7 3.5 6.9 5.3 5.0 5.5 5.1 5.7 5.2 6.1 5.8 6.3 6.0 5.0 4.9 5.2 5.1 7.6 5.4 7.7 5.9 7.9 6.2 EER Q l/s Máx. Nom. Nom. 5.3 3.9 5.5 4.2 5.7 4.6 6.1 5.0 6.3 5.3 0.75 1.00 0.79 1.05 0.86 1.14 0.99 1.32 1.06 1.41 15.4 Pf kW Máx. Nom. 9.9 15.4 3.4 4.4 3.5 4.6 3.6 4.8 3.8 4.8 4.0 4.9 1.7 3.9 1.7 4.0 0.7 1.7 0.7 1.6 0.8 1.8 Pa kW Máx. Nom. 3.4 6.3 3.5 6.4 3.6 6.5 3.8 6.8 4.0 7.0 4.5 4.6 4.6 4.7 4.9 4.9 5.3 5.7 5.5 6.1 5.7 3.3 6.4 3.4 9.4 4.8 9.3 6.0 9.3 5.6 15 EER Q l/s Máx. Nom. 4.5 3.9 4.6 4.1 4.9 4.4 5.3 4.9 5.5 5.2 0.73 0.98 0.78 1.03 0.85 1.12 0.98 1.31 1.06 1.43
20.5 12.8 24.5 16.3 10.5 16.3 21.6 13.5 26.3 17.8 23.3 20.4 27.3 22.0 29.8 6.2 8.1 7.0 9.5 7.1 9.9 17.8 28.7 20.4 33.3 22.0 36.3
TEMPERATURA DEL AIRE EXTERIOR EN °C Temperatura del agua de salida en °C EREBA Reversible Nom. 5 7 10 15 18 17HT 21HT 17HT 21HT 17HT 21HT 17HT 21HT 17HT 21HT 14.5 15.6 17.1 22.9 19.8 26.2 21.5 9.0 9.6 5.2 8.4 6.1 9.8 7.0 25 Pf kW Máx. Nom. 14.5 15.6 17.1 27.3 19.8 31.0 21.9 3.8 4.9 3.8 5.0 3.9 5.2 4.0 5.4 4.1 5.6 2.0 3.2 2.0 3.3 1.2 1.9 1.1 1.9 0.9 1.8 Pa kW Máx. Nom. 3.8 6.9 3.8 7.1 3.9 7.4 4.0 7.9 4.2 8.2 3.9 4.1 4.1 4.2 4.4 4.4 4.9 4.8 5.2 5.0 4.4 4.3 4.7 4.5 4.6 4.4 5.4 5.2 7.8 5.9 EER Q l/s Máx. Nom. Nom. 3.9 3.5 4.1 3.6 4.4 3.7 4.9 3.9 5.2 4.0 0.69 0.95 0.75 1.01 0.82 1.10 0.95 1.26 1.03 1.36 14.3 18.1 15.2 19.1 16.6 20.9 19.2 21.4 Pf kW Máx. Nom. 3.0 8.3 3.2 8.9 3.6 9.7 4.2 4.6 14.8 22.3 15.8 23.6 17.3 25.6 19.9 21.6 4.7 5.8 4.8 6.0 5.0 6.4 5.2 6.8 5.4 6.6 1.3 2.5 1.3 2.5 1.3 2.7 1.2 2.7 1.2 2.8 Pa kW Máx. Nom. 5.0 8.3 5.1 8.5 5.3 8.8 5.6 9.4 5.6 9.8 3.0 3.1 3.1 3.2 3.4 3.2 3.7 3.5 4.0 4.0 2.3 3.3 2.5 3.5 2.8 3.6 3.4 4.1 3.9 4.4 35 EER Q l/s Máx. Nom. 3.0 2.7 3.1 2.8 3.3 2.9 3.6 3.1 3.8 3.2 0.68 0.86 0.73 0.91 0.79 1.00 0.92 1.15 1.03 1.26
19.9 13.8 23.8 21.1 14.7 25.2
23.9 11.2 29.1 26.4 12.2 31.3
28.3 10.8 33.3
TEMPERATURA DEL AIRE EXTERIOR EN °C Temperatura del agua de salida en °C EREBA Reversible Nom. 5 7 10 15 18 17HT 21HT 17HT 21HT 17HT 21HT 17HT 21HT 17HT 21HT 12.3 15.2 13.1 16.1 14.3 17.6 16.7 20.2 18.5 21.9 4.0 6.5 4.2 6.9 4.7 7.6 5.4 8.8 5.9 9.6 45 Pf kW Máx. Nom. 12.3 16.4 13.1 17.4 14.4 19.0 16.7 21.8 18.5 23.6 5.2 6.4 5.3 6.6 5.5 6.8 5.8 7.1 5.9 7.3 2.7 2.8 2.8 2.8 2.8 2.9 2.9 3.0 2.9 3.0 Pa kW Máx. Nom. 5.2 7.1 5.3 7.2 5.5 7.5 5.8 7.9 5.9 8.1 2.4 2.4 2.5 2.5 2.6 2.6 2.9 2.8 3.1 3.0 1.4 2.3 1.5 2.4 1.7 2.6 1.9 3.0 2.0 3.2 EER Q l/s Máx. Nom. 2.4 2.3 2.5 2.4 2.6 2.6 2.9 2.8 3.1 2.9 0.58 0.72 0.62 0.77 0.69 0.84 0.80 0.97 0.89 1.05
Diferencia de temperatura de entrada/salida del agua: 5 °K Factor de ensuciamiento: 0 m².K/W Agua pura Rendimientos de acuerdo con la norma EN14511-3: 2011
36
BOMBAS DE CALOR - CLIMATIZACIÓN - REFRIGERACIÓN - TRATAMIENTO DE AIRE - INTERCAMBIOS TÉRMICOS - NE 17.01 A