references
Enfriadora y Bomba de calor reversible aire - agua
VERSIÓN STD:
CARACTERÍSTICAS TÉCNICAS
90 V STD
17.70 7.75 EER ESEER (kW) 2.29 2.61 21.80 7.31 COP SCOP 2.97 3.11 121 % Prated (kW) SCOP 16.77 3.59 140 % Prated (kW) 12.73 6500
CIATCooler LP/ILP
(kW) Potencias de refrigeración Potencia absorbida neta Rendimiento neto Rendimiento estacional (kW)
100 V STD
21.10 9.15 2.31 2.59 26.10 8.90 2.94 3.12 122 % 19.19 3.63 142 % 14.70 7000
120 V STD
25.20 10.00 2.51 2.81 29.70 9.90 3.00 3.07 120 % 21.82 3.57 140 % 16.72 10000
160 V STD
32.70 12.60 2.60 2.94 38.30 12.90 2.97 2.95 115 % 26.33 3.42 134 % 24.30 12200
180 V STD
36.00 14.40 2.49 2.85 42.60 14.20 3.01 2.95 115 % 31.31 3.35 131 % 27.32 12200 20
200 V STD
43.70 18.80 2.32 2.71 51.60 18.40 2.80 3.07 120 % 38.59 3.42 134 % 34.90 16000
240 V STD
49.30 19.70 2.51 2.97 58.50 19.60 2.99 3.07 120 % 41.71 3.71 145 % 39.44 20000
280 V STD
55.80 22.40 2.49 2.98 66.90 22.40 2.98 2.95 115 % 44.94 3.66 143 % 42.83 24400
320 V STD
68.10 24.90 2.73 3.29 76.60 24.80 3.08 2.95 115 % 51.08 3.61 141 % 47.04 24400
360 V STD
74.30 28.70 2.59 3.14 84.80 28.20 3.01 3.17 124 % 65.47 3.71 145 % 58.00 24400
Potencia absorbida neta Rendimiento neto Potencias de calefacción Rendimiento estacional Clima medio
(kW)
Rendimiento estacional Clima cálido Caudal de aire nominal (m3/h) Presión estática disponible (mm CA) Ventilador centrífugo del circuito exterior Número ventiladores Potencia del motor (kW) Potencia absorbida (kW) Velocidad (rpm) Caudal de agua nominal (m3/h) Caudal mínimo de agua (m3/h) Caudal máximo de agua (m3/h) Tipo de conexiones hidráulicas Diámetro de las conexiones Tipo N.º de compresores/etapas/circuitos Compresor Tipo de aceite Volumen de aceite (l) Tipo Refrigerante
1 2.2 1.46 973 3.1 2.3 2.2 1.77 1027 3.7 3.2 2.7 7.4 3.0 2.33 837 4.3 2.9 3.1 8.8 4.0 2.83 734 5.7 4.7 4.1 11.3 4.0 2.83 734 6.2 2.9 4.3 12.7 2 x 3,0 4.68 1082 7.5 4.2 4.7 15.0 2 x 3,0 4.66 837 8.5 3.2 6.2 17.2
2 2 x 4,0 5.3 705 9.6 4.0 7.2 19.2 2 x 4,0 5.66 734 11.7 2.1 8.3 23.6 2 x 4,0 5.66 734 12.8 2.6 8.6 26.0
Circuito interior
2.2 6.2
Roscas GAS 1 1/4" m 1 1/2" m Scroll 1/1/1 2/2/1 Copeland 3MAF 32 cST. Danfoss POE 160 SZ. ICI Emkarate RL 32 CF. Mobil EAL Artic 22 CC 3.0 3.3 3.3 3.3 6.2 2 x 3,3 2 x 3,3 2 x 3,3 2 x 3,3 2 x 6,2 R-410A 2 088 2" m
Carga (kg) Impacto medioambiental (tCO2 e)
5.9 12.3
6.1 12.7
6.6 13.8
6.9 14.4
7.6 15.9
9.2 19.2
12.3 25.7
12.4 25.9
14.9 31.1
15.4 32.2
Características
Tensión de red Acometida Compresor (A) 15.2 5.0 0.9 21.1 1117 860 1447 302 306 310 315 372 379 17.3 5.0 0.9 23.2 20.5 6.9 0.9 28.3
400 V / III ph / 50 Hz (±10 %) 3 hilos + tierra + neutro 25.4 8.9 0.9 35.2 1398 860 1727 390 397 388 396 30.5 8.9 0.9 40.3 34.6 13.8 1.8 50.2 2113 860 1447 564 579 644 659 41.0 13.8 1.8 56.6 45.9 17.8 1.8 65.5 2673 860 1727 676 692 710 728 716 733 50.8 17.8 1.8 70.4 61.0 17.8 1.8 80.6
Intensidad máxima absorbida
Ventilador (A) Control (A) Total (A) Largo (mm)
Dimensiones
Ancho (mm) Alto (mm)
Peso
Vacío (kg) En funcionamiento (kg)
exterior de 35ºC. EN-14511-2013 para unas condiciones de temperatura de salida de agua de 45ºC y de temperatura exterior de 6ºC BH. Potencia total absorbida por los compresores, los motoventiladores y la regulación electrónica en condiciones nominales, calculada de acuerdo con la norma EN-14511-2013. Las funciones opcionales no están incluidas. Valores calculados de acuerdo con la norma EN-14825-2013 para una temperatura bivalente de -5ºC en condiciones climatológicas medias y de 2ºC en climas más cálidos.
Con los soportes de transporte, la altura del equipo aumenta 106 mm.
BOMBAS DE CALOR - CLIMATIZACIÓN - REFRIGERACIÓN - TRATAMIENTO DE AIRE - INTERCAMBIOS TÉRMICOS - NE 17.01 A
181
CIATCooler LP
1