references
Luftgekühlte Inverter-Flüssigkeitskühler & reversible Luft/Wasser-Wärmepumpen
KÜHLLEISTUNGEN
GEMÄSS
EN14511-3:
AUSSENLUFTTEMPERATUR IN °C 5
Vorlauftemperatur EREBA Nur in °C Kühlbetrieb 17T 21T 17T 21T 17T 21T 17T 21T 17T 21T
15 Pf Pa Q Pf Pa Q EER EER kW kW l/s kW kW l/s Nennl. Min. Max. Nennl. Min. Max. Nennl. Min. Max. Nennl. Nennl. Min. Max. Nennl. Min. Max. Nennl. Min. Max. Nennl. 16.3 20.8 17.3 18.7 21.2 23.7 5.4 9.4 5.8 6.3 7.3 7.9 16.3 24.7 17.3 18.7 21.2 23.7 3.1 3.9 3.1 4.0 3.3 4.3 3.5 4.2 3.4 4.3 0.5 1.3 0.4 1.3 0.4 1.3 0.4 1.4 0.3 1.4 3.1 5.7 3.1 5.7 3.3 5.9 3.5 6.2 3.4 6.6 5.3 5.3 5.5 5.4 5.7 5.6 6.1 6.6 7.0 7.1 10.8 7.5 13.5 7.8 15.1 8.2 20.5 8.9 25.5 9.3 5.3 4.3 5.5 4.6 5.7 4.9 6.1 5.4 7.0 5.5 0.78 0.99 0.82 1.05 0.89 1.13 1.02 1.34 1.13 1.46 16.1 20.7 17.0 21.8 18.5 21.4 23.6 5.3 9.0 5.6 9.6 6.2 7.0 7.7 16.1 26.2 17.0 27.9 18.5 21.4 23.6 3.2 4.2 3.2 4.3 3.4 4.4 3.4 4.5 3.4 4.6 0.6 1.6 0.6 1.6 0.5 1.5 0.5 1.4 0.4 1.6 3.2 6.2 3.2 6.3 3.4 6.5 3.4 7.0 3.4 7.4 5.1 4.9 5.2 5.1 5.5 5.5 6.2 6.2 6.9 6.5 9.2 5.8 10.1 6.0 11.9 7.1 13.7 8.6 19.4 8.4 5.1 4.3 5.2 4.4 5.5 4.7 6.2 4.9 6.8 5.1 0.77 0.99 0.81 1.04 0.88 1.15 1.03 1.33 1.13 1.45
5 7 10 15 18
22.0 10.0 26.4 23.7 10.8 29.0 27.9 12.3 33.7 30.5 13.3 36.1
24.0 10.7 30.6 27.8 12.5 34.8 30.3 13.2 37.5
AUSSENLUFTTEMPERATUR IN °C Vorlauftemperatur EREBA Nur in °C Kühlbetrieb 17T 21T 17T 21T 17T 21T 17T 21T 17T 21T 35 Pf Pa Q Pf Pa Q EER EER kW kW l/s kW kW l/s Nennl. Min. Max. Nennl. Min. Max. Nennl. Min. Max. Nennl. Nennl. Min. Max. Nennl. Min. Max. Nennl. Min. Max. Nennl. 15.4 19.8 16.3 21.0 17.8 20.5 22.2 5.6 8.7 6.3 9.3 6.6 8.1 8.9 15.4 24.6 16.3 26.0 17.8 20.5 22.2 3.6 4.8 3.7 4.9 3.7 5.0 3.9 5.3 4.0 5.5 1.1 1.7 1.0 1.8 1.1 1.7 0.9 1.7 0.9 1.7 3.6 7.1 3.7 7.3 3.7 7.6 3.9 8.2 4.0 8.5 4.3 4.2 4.5 4.3 4.8 4.6 5.3 5.0 5.6 5.2 5.1 5.0 6.6 5.3 6.0 5.9 8.7 6.8 10.1 7.5 4.3 3.5 4.5 3.6 4.8 3.7 5.3 3.9 5.6 4.1 0.73 0.95 0.78 1.00 0.85 1.09 0.98 1.26 1.07 1.36 14.7 18.1 16.0 19.2 17.1 19.6 22.2 5.8 9.3 6.3 9.9 7.0 8.2 9.0 15.8 23.5 16.7 24.9 18.2 20.9 22.6 4.5 5.6 4.6 5.8 4.8 5.9 5.0 6.2 5.2 6.3 1.6 2.5 1.6 2.5 1.6 2.6 1.6 2.6 1.5 2.6 5.0 8.5 5.1 8.7 5.3 9.1 5.6 9.7 5.8 10.1 3.2 3.2 3.5 3.3 3.6 3.5 3.9 3.9 4.3 4.1 3.6 3.7 3.9 3.9 4.3 4.2 5.2 4.8 5.9 5.2 3.1 2.8 3.2 2.8 3.4 3.0 3.7 3.2 3.9 3.3 0.70 0.86 0.76 0.91 0.82 1.00 0.94 1.15 1.06 1.24 25
5 7 10 15 18
22.9 10.2 28.3 26.2 11.9 32.2 28.3 13.0 34.7
21.0 10.8 27.0 24.1 12.5 30.8 25.9 13.6 33.3
AUSSENLUFTTEMPERATUR IN °C Vorlauftemperatur EREBA Nur in °C Kühlbetrieb 17T 21T 17T 21T 17T 21T 17T 21T 17T 21T 45 Pf Pa Q EER kW kW l/s Nennl. Min. Max. Nennl. Min. Max. Nennl. Min. Max. Nennl. 13.2 16.2 14.0 17.2 15.3 7.8 9.0 8.4 9.6 9.2 13.2 17.4 14.0 18.5 15.3 5.2 6.6 5.3 6.7 5.5 6.9 5.7 7.3 5.9 7.5 3.0 3.6 3.1 3.6 3.1 3.7 3.2 3.8 3.2 3.9 5.2 7.3 5.3 7.4 5.5 7.7 5.8 8.1 5.9 8.4 2.5 2.5 2.6 2.6 2.8 2.7 3.1 3.0 3.2 3.1 2.6 2.5 2.7 2.6 2.9 2.9 3.4 3.2 3.6 3.4 2.5 2.4 2.6 2.5 2.8 2.6 3.1 2.9 3.2 3.0 0.63 0.77 0.67 0.82 0.73 0.90 0.84 1.04 0.92 1.13
5 7 10 15 18
18.8 10.5 20.2 17.6 10.7 17.6 21.7 12.2 23.3 19.1 11.7 19.1 23.5 13.3 25.2
Wassertemperaturdifferenz zwischen Ein- und Austritt des Verflüssigers: 5 K Verschmutzungsfaktor: 0 m² K/W Reines Wasser Leistungsangaben gemäß EN14511-3:2011.
WÄRMEPUMPEN - KLIMATISIERUNG - KÄLTE - LUFTBEHANDLUNG - WÄRMEAUSTAUSCH - ND 17.01 A
37
Ereba 17-21
1
EREBA Nur Kühlbetrieb