references
Luftgekühlte Inverter-Flüssigkeitskühler & reversible Luft/Wasser-Wärmepumpen
Ereba 17-21
KÜHLLEISTUNGEN
EREBA reversibel
AUSSENLUFTTEMPERATUR IN °C Vorlauftemperatur EREBA in °C reversibel 17HT 21HT 17HT 21HT 17HT 21HT 17HT 21HT 17HT 21HT 15 Pf Pa Q Pf Pa Q EER EER kW kW l/s kW kW l/s Nennl. Min. Max. Nennl. Min. Max. Nennl. Min. Max. Nennl. Nennl. Min. Max. Nennl. Min. Max. Nennl. Min. Max. Nennl. 15.7 13.3 15.7 20.9 14.4 24.5 16.6 14.1 16.6 22.0 15.2 26.4 18.0 20.6 22.2 7.9 8.5 9.1 18.0 20.6 22.2 23.8 16.5 29.0 27.5 18.8 33.3 29.5 20.3 36.3 3.0 4.2 3.0 4.4 3.2 4.6 3.4 4.7 3.5 5.0 2.7 3.0 2.7 3.0 1.1 3.1 1.1 3.2 1.2 3.3 3.0 6.3 3.0 6.3 3.2 6.4 3.4 6.7 3.5 6.9 5.3 5.0 5.5 5.1 5.7 5.2 6.1 5.8 6.3 6.0 5.0 4.9 5.2 5.1 7.6 5.4 7.7 5.9 7.9 6.2 5.3 3.9 5.5 4.2 5.7 4.6 6.1 5.0 6.3 5.3 0.75 1.00 0.79 1.05 0.86 1.14 0.99 1.32 1.06 1.41 15.4 9.9 15.4 3.4 4.4 3.5 4.6 3.6 4.8 3.8 4.8 4.0 4.9 1.7 3.9 1.7 4.0 0.7 1.7 0.7 1.6 0.8 1.8 3.4 6.3 3.5 6.4 3.6 6.5 3.8 6.8 4.0 7.0 4.5 4.6 4.6 4.7 4.9 4.9 5.3 5.7 5.5 6.1 5.7 3.3 6.4 3.4 9.4 4.8 9.3 6.0 9.3 5.6 4.5 3.9 4.6 4.1 4.9 4.4 5.3 4.9 5.5 5.2 0.73 0.98 0.78 1.03 0.85 1.12 0.98 1.31 1.06 1.43 20.5 12.8 24.5 16.3 10.5 16.3 21.6 13.5 26.3 17.8 23.3 20.4 27.3 22.0 29.8 6.2 8.1 7.0 9.5 7.1 9.9 17.8 28.7 20.4 33.3 22.0 36.3 5
GEMÄSS
EN14511-3
5 7 10 15 18
AUSSENLUFTTEMPERATUR IN °C Vorlauftemperatur EREBA in °C reversibel 17HT 21HT 17HT 21HT 17HT 21HT 17HT 21HT 17HT 21HT 35 Pf Pa Q Pf Pa Q EER EER kW kW l/s kW kW l/s Nennl. Min. Max. Nennl. Min. Max. Nennl. Min. Max. Nennl. Nennl. Min. Max. Nennl. Min. Max. Nennl. Min. Max. Nennl. 14.5 15.6 17.1 22.9 19.8 26.2 21.5 9.0 9.6 5.2 8.4 6.1 9.8 7.0 14.5 15.6 17.1 27.3 19.8 31.0 21.9 3.8 4.9 3.8 5.0 3.9 5.2 4.0 5.4 4.1 5.6 2.0 3.2 2.0 3.3 1.2 1.9 1.1 1.9 0.9 1.8 3.8 6.9 3.8 7.1 3.9 7.4 4.0 7.9 4.2 8.2 3.9 4.1 4.1 4.2 4.4 4.4 4.9 4.8 5.2 5.0 4.4 4.3 4.7 4.5 4.6 4.4 5.4 5.2 7.8 5.9 3.9 3.5 4.1 3.6 4.4 3.7 4.9 3.9 5.2 4.0 0.69 0.95 0.75 1.01 0.82 1.10 0.95 1.26 1.03 1.36 14.3 18.1 15.2 19.1 16.6 20.9 19.2 21.4 3.0 8.3 3.2 8.9 3.6 9.7 4.2 4.6 14.8 22.3 15.8 23.6 17.3 25.6 19.9 21.6 4.7 5.8 4.8 6.0 5.0 6.4 5.2 6.8 5.4 6.6 1.3 2.5 1.3 2.5 1.3 2.7 1.2 2.7 1.2 2.8 5.0 8.3 5.1 8.5 5.3 8.8 5.6 9.4 5.6 9.8 3.0 3.1 3.1 3.2 3.4 3.2 3.7 3.5 4.0 4.0 2.3 3.3 2.5 3.5 2.8 3.6 3.4 4.1 3.9 4.4 3.0 2.7 3.1 2.8 3.3 2.9 3.6 3.1 3.8 3.2 0.68 0.86 0.73 0.91 0.79 1.00 0.92 1.15 1.03 1.26 19.9 13.8 23.8 21.1 14.7 25.2 25
5 7 10 15 18
23.9 11.2 29.1 26.4 12.2 31.3
28.3 10.8 33.3
AUSSENLUFTTEMPERATUR IN °C Vorlauftemperatur EREBA in °C reversibel 17HT 21HT 17HT 21HT 17HT 21HT 17HT 21HT 17HT 21HT 45 Pf Pa Q EER kW kW l/s Nennl. Min. Max. Nennl. Min. Max. Nennl. Min. Max. Nennl. 12.3 15.2 13.1 16.1 14.3 17.6 16.7 20.2 18.5 21.9 4.0 6.5 4.2 6.9 4.7 7.6 5.4 8.8 5.9 9.6 12.3 16.4 13.1 17.4 14.4 19.0 16.7 21.8 18.5 23.6 5.2 6.4 5.3 6.6 5.5 6.8 5.8 7.1 5.9 7.3 2.7 2.8 2.8 2.8 2.8 2.9 2.9 3.0 2.9 3.0 5.2 7.1 5.3 7.2 5.5 7.5 5.8 7.9 5.9 8.1 2.4 2.4 2.5 2.5 2.6 2.6 2.9 2.8 3.1 3.0 1.4 2.3 1.5 2.4 1.7 2.6 1.9 3.0 2.0 3.2 2.4 2.3 2.5 2.4 2.6 2.6 2.9 2.8 3.1 2.9 0.58 0.72 0.62 0.77 0.69 0.84 0.80 0.97 0.89 1.05
5 7 10 15 18
Wassertemperaturdifferenz zwischen Ein- und Austritt des Verflüssigers: 5 K Verschmutzungsfaktor: 0 m² K/W Reines Wasser Leistungsangaben gemäß EN14511-3:2011.
36
WÄRMEPUMPEN - KLIMATISIERUNG - KÄLTE - LUFTBEHANDLUNG - WÄRMEAUSTAUSCH - ND 17.01 A